Facility Alarms Configuration Command Reference

Command Hierarchies

Facility Alarm Configuration Commands

config
— system
alarms
max-cleared max-alarms
[no] shutdown

Command Descriptions

Generic Commands

alarms

Syntax 
alarms
Context 
config>system
Description 

This command enters the context to configure facility alarm parameters. Alarm support is intended to cover a focused subset of router states that are likely to indicate service impacts (or imminent service impacts) related to the overall state of hardware assemblies (cards, fans, links, and so on).

max-cleared

Syntax 
max-cleared max-alarms
Context 
config>system>alarms
Description 

This command configures the maximum number of cleared alarms that the system will store and display.

Default 

500

Parameters 
max-alarms—
Specifies the maximum number of cleared alarms.

shutdown

Syntax 
[no] shutdown
Context 
config>system>alarms
Description 

This command enables or disables the Facility Alarm functionality. When enabled, the Facility Alarm sub-system tracks active and cleared facility alarms and controls the Alarm LEDs on the CPMs/CFMs. When Facility Alarm functionality is enabled, the alarms are viewed using the show system alarms command(s).

Default 

no shutdown